Hydraulic

Are you sure your hydraulic machine is broken?

Speaking about questions I get from members, there's a very valuable lesson in this one:

"We have some problems with a Denison hydraulic transmission pump P24S 2R1C 9A2. Oil temperature rises from 20 to 50 Celsius within 15-20 minutes of only light operation (65 bar working pressure). The pump was sent to a local workshop for repair and cost us US10,000 dollars and yet the problem remains. The hydraulic repair shop sent an engineer to investigate but he couldn't solve it?"

So the hydraulic pump wasn't the cause of the problem. Ouch! An expensive mistake. And one I've seen made all too often by hydraulic equipment users. But is there really a problem here at all?

Hydraulic oil temperature is rising to 50 Celsius within 20 minutes of operation. No big deal. Since this member is from Singapore, I would expect him to be using a VG68 hydraulic oil. Depending on the viscosity index of the particular oil he's using, optimum operating viscosity is achieved between 55 and 78 Celsius. So after 20 minutes, the system isn't even at operating temperature. Of itself, no cause for alarm.

But why does this hydraulic system heat up so fast? Well this is a big transmission pump - 24 cubic inches or 400 cubic centimeters per rev. So it will have a big charge pump. As big as 4.8 cubic inches or 80 cubic centimeters per rev. If these pumps are turning at 1500 rpm and charge pressure is set at 23 bar, the charge pump is generating 4600 watts of pure heat load. That's equivalent to the power of two electric kettles.

And being a hydrostatic transmission, it won't have a large reservoir - perhaps as small as half the available charge pump flow per minute. Which in this case, could be as little as 16 gallons or 60 liters. So the transmission's inbuilt heating element, a.k.a charge pump, will soon warm up this volume of hydraulic oil - even with the transmission in neutral.

Based on my long experience in the hydraulics business, the whole issue of efficiency, heat-load and cooling - and its inter-relationship with viscosity and lubrication, is grossly misunderstood by hydraulic equipment users. And as the above example illustrates, it can get them into a heap of trouble.

Which is why during the Breakdown Prevention seminars I present, I spend nearly half a day dealing with this whole issue. You can watch a short video clip of it, where I explain why the charge pump in a hydrostatic transmission is pure heat load - and the reason why this member blew $10,000 on an unnecessary pump overhaul. Watch the video here.

If you enjoyed this article, you'll love Brendan Casey's Inside Hydraulics newsletter. It gives you real-life, how-to-do-it, nuts-and-bolts, hydraulics know-how – information you can use today. Listen to what a few of his subscribers have to say:

Can't Put It Down
“I get magazines and e-mails like this all the time. I never find time to read them. I decided to read Issue #30 and I couldn't put it down. I'll make time from now on.”

Richard A. Shade, CFPS
Project Engineer (Hydraulic Design)
JLG Industries Inc.

So Valuable It Earned Me A Raise
“The knowledge I've gained from this newsletter has been so valuable it has earned me a raise!”

Jack Bergstrom
Heavy Equipment Mechanic
Sharpe Equipment Inc.

Love It - Keep Them Coming
“I just love this newsletter. As a Hydraulics Instructor for Eaton, I make copies and distribute them to my students as I address various topics... Keep 'em coming.”

Michael S Lawrence
Hydraulics Instructor
Eaton Hydraulics Inc.

Here's a sample of what's covered in this powerful newsletter: troubleshooting, contamination control, component repair and testing, preventative maintenance, failure analysis, and much, much more!